Overview
- 1 FDA inspection is on record.
- 1 inspection produced a Form 483.
- The most recent recorded inspection date is 2019-07-15.
At a glance
Inspections
1
Form 483s
1
EIRs
0
Last outcome
Form 483
Inspection history
FDA inspections on record, most recent first.
| Inspection | Category | Outcome | Form 483 |
|---|---|---|---|
| 12 Jul 2019 – 15 Jul 2019 | Foods & Cosmetics | 483 | View 483 → |
Observations on record
Form 483 observations cited at this site, most recent first.
15 Jul 2019
21 CFR 113.100(b)
Recording device records - dated; retort number
Cited by Edith M Gonzalez, Daniel C Geffin
15 Jul 2019
21 CFR 113.40(a)(8)
Still steam retorts: Bleeder not wide open during process
Cited by Edith M Gonzalez, Daniel C Geffin
Investigators
FDA investigators tied to this site in the record.
Edith M Gonzalez1 insp.
Daniel C Geffin1 insp.
Recurring citations
CFR citation patterns observed across this site's inspections.
| Citation | What it covers | Cited |
|---|---|---|
| 21 CFR 113.89 | Cited across public-safe Form 483 observations | 2x |
| 21 CFR 113.100(b) | Cited across public-safe Form 483 observations | 1x |
| 21 CFR 113.40(a)(11) | Cited across public-safe Form 483 observations | 1x |
| 21 CFR 113.40(a)(8) | Cited across public-safe Form 483 observations | 1x |
| 21 CFR 113.60(c) | Cited across public-safe Form 483 observations | 1x |
| 21 CFR 117.40 | Cited across public-safe Form 483 observations | 1x |
Full site report
Get the verbatim findings behind Suqian Cannery And Food Corp Ltd's 1 Form 483
Recurring CFR citations, so your team knows what this site gets cited for.
- The site's full inspection history, with every Form 483 and its outcome
- Warning letters and recalls tied to the company behind it
- Whether recurring CFR citations get closed out or repeat