FDA-Inspected Site

Steribite, LLC

2 FDA inspections are on record for Steribite, LLC in Wooster, United States.

483· Form 483 issued

Wooster, United States · Last updated August 15, 2026

Overview

  • 2 FDA inspections are on record.
  • 1 inspection produced a Form 483.
  • The most recent recorded inspection date is 2026-04-08.

At a glance

Inspections

2

Form 483s

1

EIRs

0

Last outcome

Form 483

Inspection history

FDA inspections on record, most recent first.

InspectionCategoryOutcomeForm 483
25 Mar 2026 – 8 Apr 2026Medical Devices & Rad Health483View 483 →
14 Dec 2017 – 21 Dec 2017Medical Devices & Rad HealthClean

Observations on record

Form 483 observations cited at this site, most recent first.

8 Apr 2026
21 CFR 830.300(a)

Devices subject to device identification GUDID data submission requirements.

Cited by Javonica F Penn

8 Apr 2026
ISO 13485:2016 Clause 4.1.2

Risk-based approach not applied to QMS processes

Cited by Javonica F Penn

8 Apr 2026
ISO 13485:2016 Clause 4.1.5

External party controls do not include written quality agreements

Cited by Javonica F Penn

8 Apr 2026
ISO 13485:2016 Clause 4.2.3

Medical device file not established and maintained

Cited by Javonica F Penn

8 Apr 2026
ISO 13485:2016 Clause 5.6.1

QMS not reviewed by top management at documented planned intervals

Cited by Javonica F Penn

Investigators

FDA investigators tied to this site in the record.

Recurring citations

CFR citation patterns observed across this site's inspections.

CitationWhat it coversCited
ISO 13485:2016 Clause 7.5.6Cited across public-safe Form 483 observations2x
21 CFR 830.300(a)Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 4.1.2Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 4.1.5Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 4.2.3Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 5.6.1Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 6.2(e)Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 7.1Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 7.3.1Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 7.5.1Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 8.3.1Cited across public-safe Form 483 observations1x

Full site report

Get the verbatim findings behind Steribite, LLC's 1 Form 483

Recurring CFR citations, so your team knows what this site gets cited for.

  • The site's full inspection history, with every Form 483 and its outcome
  • Warning letters and recalls tied to the company behind it
  • Whether recurring CFR citations get closed out or repeat