FDA-Inspected Site

RWM Technologies LLC

11 FDA inspections are on record for RWM Technologies LLC in Chattanooga, United States.

483· Form 483 issued

Chattanooga, United States · Last updated July 10, 2026

Overview

  • 11 FDA inspections are on record.
  • 4 inspections produced a Form 483.
  • The most recent recorded inspection date is 2025-12-12.

At a glance

Inspections

11

Form 483s

4

EIRs

0

Last outcome

Form 483

Inspection history

FDA inspections on record, most recent first.

InspectionCategoryOutcomeForm 483
8 Dec 2025 – 12 Dec 2025Human Drugs483View 483 →
9 Jan 2023 – 13 Jan 2023Human Drugs483View 483 →
20 Jul 2022Foods & CosmeticsClean
19 Mar 2019 – 26 Mar 2019Foods & Cosmetics483View 483 →
26 Apr 2016 – 27 Apr 2016Animal Drugs & FeedsClean
15 Sep 2015Animal Drugs & FeedsClean
12 May 2014 – 13 May 2014Animal Drugs & FeedsClean
27 Feb 2013 – 28 Feb 2013Animal Drugs & FeedsClean
6 Feb 2012Not recordedClean
4 Oct 2010Not recorded483View 483 →
27 Jan 2010Not recordedClean

Observations on record

Form 483 observations cited at this site, most recent first.

12 Dec 2025
21 CFR 211.165(b)

Microbiological testing

Cited by Michael Z Weigman

12 Dec 2025
21 CFR 211.166(a)

Written program not followed

Cited by Michael Z Weigman

12 Dec 2025
21 CFR 211.22(d)

Procedures not in writing, fully followed

Cited by Michael Z Weigman

12 Dec 2025
21 CFR 211.42(a)

Buildings of Suitable Size, Construction, Location

Cited by Michael Z Weigman

12 Dec 2025
21 CFR 211.84(d)(1)

Component identity verification

Cited by Michael Z Weigman

Investigators

FDA investigators tied to this site in the record.

State Agency3 insp.
cntrctmntr Willey1 insp.
cntrctmntr Mahaffey1 insp.

Recurring citations

CFR citation patterns observed across this site's inspections.

CitationWhat it coversCited
21 CFR 111.420(c)Cited across public-safe Form 483 observations6x
21 CFR 111.70(f)Cited across public-safe Form 483 observations6x
21 CFR 111.75(a)(2)(ii)(A)Cited across public-safe Form 483 observations6x
21 CFR 111.75(f)(2)Cited across public-safe Form 483 observations6x
21 CFR 211.22(d)Cited across public-safe Form 483 observations3x
21 CFR 211.166(a)Cited across public-safe Form 483 observations2x
21 CFR 211.100(a)Cited across public-safe Form 483 observations1x
21 CFR 211.100(b)Cited across public-safe Form 483 observations1x
21 CFR 211.160(a)Cited across public-safe Form 483 observations1x
21 CFR 211.165(b)Cited across public-safe Form 483 observations1x
21 CFR 211.165(d)Cited across public-safe Form 483 observations1x
21 CFR 211.180(b)Cited across public-safe Form 483 observations1x
21 CFR 211.180(e)(1)Cited across public-safe Form 483 observations1x
21 CFR 211.188(b)(1)Cited across public-safe Form 483 observations1x
21 CFR 211.188(b)(11)Cited across public-safe Form 483 observations1x
21 CFR 211.188(b)(13)Cited across public-safe Form 483 observations1x
21 CFR 211.188(b)(6)Cited across public-safe Form 483 observations1x
21 CFR 211.188(b)(8)Cited across public-safe Form 483 observations1x
21 CFR 211.192Cited across public-safe Form 483 observations1x
21 CFR 211.42(a)Cited across public-safe Form 483 observations1x
21 CFR 211.80(a)Cited across public-safe Form 483 observations1x
21 CFR 211.84(d)(1)Cited across public-safe Form 483 observations1x
21 CFR 211.84(d)(2)Cited across public-safe Form 483 observations1x
21 CFR 211.84(d)(3)Cited across public-safe Form 483 observations1x

Full site report

Get the verbatim findings behind RWM Technologies LLC's 4 Form 483s

Source PDFs, verbatim observations, and recurring CFR citations, so your team knows what this site gets cited for.

  • The site's full inspection history, with every Form 483 and its outcome
  • Warning letters and recalls tied to the company behind it
  • Whether recurring CFR citations get closed out or repeat