FDA-Inspected Site

Midmark Corporation

6 FDA inspections are on record for Midmark Corporation in Versailles, United States.

483· Form 483 issued

Versailles, United States · Last updated July 10, 2026

Overview

  • 6 FDA inspections are on record.
  • 4 inspections produced a Form 483.
  • The most recent recorded inspection date is 2018-04-02.

At a glance

Inspections

6

Form 483s

4

EIRs

0

Last outcome

Form 483

Inspection history

FDA inspections on record, most recent first.

InspectionCategoryOutcomeForm 483
28 Mar 2018 – 2 Apr 2018Medical Devices & Rad Health483View 483 →
6 Dec 2016 – 9 Dec 2016Medical Devices & Rad HealthClean
19 May 2014 – 9 Jun 2014Medical Devices & Rad Health483View 483 →
28 Jun 2012Not recorded483View 483 →
12 Sep 2011Not recordedWLView 483 →
17 Nov 2006Not recordedClean

Observations on record

Form 483 observations cited at this site, most recent first.

2 Apr 2018
21 CFR 820.100(a)

Lack of or inadequate procedures

Cited by Christina L Bigham

9 Jun 2014
21 CFR 803.17

Lack of Written MDR Procedures

Cited by Rosanna M Goodrich

9 Jun 2014
21 CFR 820.30(g)

Design Validation - Risk analysis not performed/inadequate

Cited by Rosanna M Goodrich

9 Jun 2014
21 CFR 820.30(i)

Design changes - Lack of or Inadequate Procedures

Cited by Rosanna M Goodrich

9 Jun 2014
21 CFR 820.40

Procedures not adequately established or maintained

Cited by Rosanna M Goodrich

Investigators

FDA investigators tied to this site in the record.

Recurring citations

CFR citation patterns observed across this site's inspections.

CitationWhat it coversCited
21 CFR 820.100(a)Cited across public-safe Form 483 observations4x
21 CFR 803.17Cited across public-safe Form 483 observations2x
21 CFR 820.30(g)Cited across public-safe Form 483 observations2x
21 CFR 820.50(a)(3)Cited across public-safe Form 483 observations2x
21 CFR 820.180(b)Cited across public-safe Form 483 observations1x
21 CFR 820.198(a)Cited across public-safe Form 483 observations1x
21 CFR 820.198(c)Cited across public-safe Form 483 observations1x
21 CFR 820.200(a)Cited across public-safe Form 483 observations1x
21 CFR 820.250(a)Cited across public-safe Form 483 observations1x
21 CFR 820.30(i)Cited across public-safe Form 483 observations1x
21 CFR 820.40Cited across public-safe Form 483 observations1x
21 CFR 820.50Cited across public-safe Form 483 observations1x
21 CFR 820.50(a)Cited across public-safe Form 483 observations1x
21 CFR 820.70(a)Cited across public-safe Form 483 observations1x
21 CFR 820.90(a)Cited across public-safe Form 483 observations1x

Full site report

Get the verbatim findings behind Midmark Corporation's 4 Form 483s

Source PDFs, verbatim observations, and recurring CFR citations, so your team knows what this site gets cited for.

  • The site's full inspection history, with every Form 483 and its outcome
  • Warning letters and recalls tied to the company behind it
  • Whether recurring CFR citations get closed out or repeat