FDA-Inspected Site

Maquet Cardiovascular, LLC

10 FDA inspections are on record for Maquet Cardiovascular, LLC in Wayne, United States.

483· Form 483 issued

Wayne, United States · Last updated July 10, 2026

Overview

  • 10 FDA inspections are on record.
  • 8 inspections produced a Form 483.
  • The most recent recorded inspection date is 2024-07-11.

At a glance

Inspections

10

Form 483s

8

EIRs

0

Last outcome

Form 483

Inspection history

FDA inspections on record, most recent first.

InspectionCategoryOutcomeForm 483
11 Mar 2024 – 11 Jul 2024Medical Devices & Rad Health483View 483 →
25 Aug 2020 – 26 Feb 2021Medical Devices & Rad Health483View 483 →
23 May 2016 – 29 Sep 2016Medical Devices & Rad Health483View 483 →
1 Jul 2013 – 16 Oct 2013Medical Devices & Rad Health483View 483 →
14 Jun 2012Not recorded483View 483 →
1 Apr 2011Not recorded483View 483 →
14 May 2010Not recordedWLView 483 →
17 Apr 2009Not recorded483On file
25 Oct 2006Not recordedClean
14 Jul 2005Not recordedClean

Observations on record

Form 483 observations cited at this site, most recent first.

11 Jul 2024
21 CFR 803.50(a)(1)

Report of Death or Serious Injury

Cited by Melissa A Zuppe, Colin E Tack, Monica L Gutierrez

11 Jul 2024
21 CFR 803.50(a)(2)

Individual Report of Malfunction

Cited by Melissa A Zuppe, Colin E Tack, Monica L Gutierrez

11 Jul 2024
21 CFR 803.56

Submission of Supplement to Individual Report Within One Month

Cited by Melissa A Zuppe, Colin E Tack, Monica L Gutierrez

11 Jul 2024
21 CFR 820.100(a)

Lack of or inadequate procedures

Cited by Melissa A Zuppe, Colin E Tack, Monica L Gutierrez

11 Jul 2024
21 CFR 820.198(a)

Lack of or inadequate complaint procedures

Cited by Melissa A Zuppe, Colin E Tack, Monica L Gutierrez

Investigators

FDA investigators tied to this site in the record.

Recurring citations

CFR citation patterns observed across this site's inspections.

CitationWhat it coversCited
21 CFR 820.30(g)Cited across public-safe Form 483 observations17x
21 CFR 803.50(a)(1)Cited across public-safe Form 483 observations6x
21 CFR 803.50(a)(2)Cited across public-safe Form 483 observations6x
21 CFR 820.100(a)Cited across public-safe Form 483 observations6x
21 CFR 820.198(a)Cited across public-safe Form 483 observations5x
21 CFR 803.56Cited across public-safe Form 483 observations4x
21 CFR 820.75(a)Cited across public-safe Form 483 observations4x
21 CFR 820.198(d)Cited across public-safe Form 483 observations3x
21 CFR 820.75(c)Cited across public-safe Form 483 observations3x
21 CFR 820.198(b)Cited across public-safe Form 483 observations2x
21 CFR 820.20(c)Cited across public-safe Form 483 observations2x
21 CFR 820.25(a)Cited across public-safe Form 483 observations2x
21 CFR 820.25(b)Cited across public-safe Form 483 observations2x
21 CFR 820.250(a)Cited across public-safe Form 483 observations2x
21 CFR 820.30(i)Cited across public-safe Form 483 observations2x
21 CFR 820.70(c)Cited across public-safe Form 483 observations2x
21 CFR 820.70(e)Cited across public-safe Form 483 observations2x
21 CFR 820.75(b)Cited across public-safe Form 483 observations2x
21 CFR 820.90(a)Cited across public-safe Form 483 observations2x
21 CFR 803.17(a)(2)Cited across public-safe Form 483 observations1x
21 CFR 803.52(f)(1)Cited across public-safe Form 483 observations1x
21 CFR 806.10(a)(1)Cited across public-safe Form 483 observations1x
21 CFR 806.10(b)Cited across public-safe Form 483 observations1x
21 CFR 820.180Cited across public-safe Form 483 observations1x
21 CFR 820.198(c)Cited across public-safe Form 483 observations1x
21 CFR 820.30(e)Cited across public-safe Form 483 observations1x
21 CFR 820.30(h)Cited across public-safe Form 483 observations1x
21 CFR 820.40Cited across public-safe Form 483 observations1x
21 CFR 820.40(a)Cited across public-safe Form 483 observations1x
21 CFR 820.50Cited across public-safe Form 483 observations1x
21 CFR 820.50(a)Cited across public-safe Form 483 observations1x
21 CFR 820.50(a)(3)Cited across public-safe Form 483 observations1x
21 CFR 820.70(d)Cited across public-safe Form 483 observations1x
21 CFR 820.75(b)(2)Cited across public-safe Form 483 observations1x
21 CFR 820.80(b)Cited across public-safe Form 483 observations1x
21 CFR 820.90(b)(1)Cited across public-safe Form 483 observations1x

Full site report

Get the verbatim findings behind Maquet Cardiovascular, LLC's 8 Form 483s

Source PDFs, verbatim observations, and recurring CFR citations, so your team knows what this site gets cited for.

  • The site's full inspection history, with every Form 483 and its outcome
  • Warning letters and recalls tied to the company behind it
  • Whether recurring CFR citations get closed out or repeat