FDA-Inspected Site

Linvatec Corp.

8 FDA inspections are on record for Linvatec Corp. in Largo, United States.

483· Form 483 issued

Largo, United States · Last updated August 15, 2026

Overview

  • 8 FDA inspections are on record.
  • 5 inspections produced a Form 483.
  • The most recent recorded inspection date is 2026-03-24.

At a glance

Inspections

8

Form 483s

5

EIRs

0

Last outcome

Form 483

Inspection history

FDA inspections on record, most recent first.

InspectionCategoryOutcomeForm 483
16 Mar 2026 – 24 Mar 2026Medical Devices & Rad Health483View 483 →
12 Dec 2023 – 14 Dec 2023Medical Devices & Rad HealthClean
31 Oct 2017 – 3 Nov 2017Medical Devices & Rad Health483On file
31 Jul 2013 – 6 Aug 2013Medical Devices & Rad HealthClean
25 Mar 2011Not recorded483View 483 →
14 Oct 2009Not recorded483View 483 →
26 Mar 2009Not recorded483View 483 →
8 Dec 2004Not recordedClean

Observations on record

Form 483 observations cited at this site, most recent first.

24 Mar 2026
ISO 13485:2016 Clause 4.1.2

Risk-based approach not applied to QMS processes

Cited by Monica C Burgos Garcia, Lorraine N Williams

24 Mar 2026
ISO 13485:2016 Clause 7.5.1

Production and service provision not adequate

Cited by Monica C Burgos Garcia, Lorraine N Williams

24 Mar 2026
ISO 13485:2016 Clause 8.2.1

Information gathered in feedback process not used as input into risk management

Cited by Monica C Burgos Garcia, Lorraine N Williams

24 Mar 2026
ISO 13485:2016 Clause 8.3.1

Nonconforming product not identified and controlled

Cited by Monica C Burgos Garcia, Lorraine N Williams

24 Mar 2026
ISO 13485:2016 Clause 8.5.2

Corrective action not taken

Cited by Monica C Burgos Garcia, Lorraine N Williams

Investigators

FDA investigators tied to this site in the record.

Lorraine N Williams1 insp.
MDSAP harperd1 insp.

Recurring citations

CFR citation patterns observed across this site's inspections.

CitationWhat it coversCited
21 CFR 803.17Cited across public-safe Form 483 observations1x
21 CFR 803.17(a)(2)Cited across public-safe Form 483 observations1x
21 CFR 806.10(a)(1)Cited across public-safe Form 483 observations1x
21 CFR 820.100(a)Cited across public-safe Form 483 observations1x
21 CFR 820.100(a)(2)Cited across public-safe Form 483 observations1x
21 CFR 820.120(d)Cited across public-safe Form 483 observations1x
21 CFR 820.198(a)Cited across public-safe Form 483 observations1x
21 CFR 820.30(c)Cited across public-safe Form 483 observations1x
21 CFR 820.30(g)Cited across public-safe Form 483 observations1x
21 CFR 820.50(a)Cited across public-safe Form 483 observations1x
21 CFR 820.75(a)Cited across public-safe Form 483 observations1x
21 CFR 820.75(c)Cited across public-safe Form 483 observations1x
21 CFR 820.80(c)Cited across public-safe Form 483 observations1x
21 CFR 820.90(b)(1)Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 4.1.2Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 7.5.1Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 8.2.1Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 8.3.1Cited across public-safe Form 483 observations1x
ISO 13485:2016 Clause 8.5.2Cited across public-safe Form 483 observations1x

Full site report

Get the verbatim findings behind Linvatec Corp.'s 5 Form 483s

Source PDFs, verbatim observations, and recurring CFR citations, so your team knows what this site gets cited for.

  • The site's full inspection history, with every Form 483 and its outcome
  • Warning letters and recalls tied to the company behind it
  • Whether recurring CFR citations get closed out or repeat