FDA-Inspected Site

Coty Lancaster SAM

2 FDA inspections are on record for Coty Lancaster SAM in Monaco, Monaco.

483· Form 483 issued

Monaco, Monaco · Last updated July 10, 2026

Overview

  • 2 FDA inspections are on record.
  • 2 inspections produced a Form 483.
  • The most recent recorded inspection date is 2016-09-16.

At a glance

Inspections

2

Form 483s

2

EIRs

0

Last outcome

Form 483

Inspection history

FDA inspections on record, most recent first.

InspectionCategoryOutcomeForm 483
12 Sep 2016 – 16 Sep 2016Human Drugs483View 483 →
1 Feb 2013Not recorded483On file

Observations on record

Form 483 observations cited at this site, most recent first.

16 Sep 2016
21 CFR 211.103

Yield calculations not verified by 2nd person

Cited by Toyin B Oladimeji

16 Sep 2016
21 CFR 211.113(a)

Procedures for non-sterile drug products

Cited by Toyin B Oladimeji

16 Sep 2016
21 CFR 211.160(a)

Following/documenting laboratory controls

Cited by Toyin B Oladimeji

16 Sep 2016
21 CFR 211.165(e)

Test methods

Cited by Toyin B Oladimeji

16 Sep 2016
21 CFR 211.192

Investigations of discrepancies, failures

Cited by Toyin B Oladimeji

Investigators

FDA investigators tied to this site in the record.

Recurring citations

CFR citation patterns observed across this site's inspections.

CitationWhat it coversCited
21 CFR 211.68(b)Cited across public-safe Form 483 observations2x
21 CFR 211.100(a)Cited across public-safe Form 483 observations1x
21 CFR 211.103Cited across public-safe Form 483 observations1x
21 CFR 211.111Cited across public-safe Form 483 observations1x
21 CFR 211.113(a)Cited across public-safe Form 483 observations1x
21 CFR 211.160(a)Cited across public-safe Form 483 observations1x
21 CFR 211.160(b)Cited across public-safe Form 483 observations1x
21 CFR 211.165(e)Cited across public-safe Form 483 observations1x
21 CFR 211.192Cited across public-safe Form 483 observations1x
21 CFR 211.194(a)Cited across public-safe Form 483 observations1x
21 CFR 211.194(a)(3)Cited across public-safe Form 483 observations1x
21 CFR 211.198(b)(2)Cited across public-safe Form 483 observations1x
21 CFR 211.22(a)Cited across public-safe Form 483 observations1x
21 CFR 211.25(a)Cited across public-safe Form 483 observations1x
21 CFR 211.42(b)Cited across public-safe Form 483 observations1x

Full site report

Get the verbatim findings behind Coty Lancaster SAM's 2 Form 483s

Verbatim observations and recurring CFR citations, so your team knows what this site gets cited for.

  • The site's full inspection history, with every Form 483 and its outcome
  • Warning letters and recalls tied to the company behind it
  • Whether recurring CFR citations get closed out or repeat