FDA-Inspected Site

Becker Orthopedic Appliance Co.

6 FDA inspections are on record for Becker Orthopedic Appliance Co. in Troy, United States.

483· Form 483 issued

Troy, United States · Last updated July 10, 2026

Overview

  • 6 FDA inspections are on record.
  • 3 inspections produced a Form 483.
  • The most recent recorded inspection date is 2018-03-22.

At a glance

Inspections

6

Form 483s

3

EIRs

0

Last outcome

Form 483

Inspection history

FDA inspections on record, most recent first.

InspectionCategoryOutcomeForm 483
20 Mar 2018 – 22 Mar 2018Medical Devices & Rad Health483On file
15 Apr 2015 – 23 Apr 2015Medical Devices & Rad Health483View 483 →
12 Jun 2013 – 14 Jun 2013Medical Devices & Rad HealthClean
7 Oct 2010Not recordedClean
12 Jun 2009Not recorded483View 483 →
10 May 2007Not recordedClean

Observations on record

Form 483 observations cited at this site, most recent first.

23 Apr 2015
21 CFR 820.198(a)

Lack of or inadequate complaint procedures

Cited by Sargum C Sood, Cynthia L Aycock, Cynthia Li

23 Apr 2015
21 CFR 820.25(b)

Training - Lack of or inadequate procedures

Cited by Sargum C Sood, Cynthia L Aycock, Cynthia Li

23 Apr 2015
21 CFR 820.30(g)

Design Validation - Risk analysis not performed/inadequate

Cited by Sargum C Sood, Cynthia L Aycock, Cynthia Li

23 Apr 2015
21 CFR 820.50(b)

Supplier notification of changes

Cited by Sargum C Sood, Cynthia L Aycock, Cynthia Li

23 Apr 2015
21 CFR 820.80(d)

Lack of or inadequate final acceptance procedures

Cited by Sargum C Sood, Cynthia L Aycock, Cynthia Li

Investigators

FDA investigators tied to this site in the record.

MDSAP WilliamsA1 insp.
Cynthia Li1 insp.

Recurring citations

CFR citation patterns observed across this site's inspections.

CitationWhat it coversCited
21 CFR 820.198(a)Cited across public-safe Form 483 observations2x
21 CFR 820.25(b)Cited across public-safe Form 483 observations2x
21 CFR 820.30(g)Cited across public-safe Form 483 observations2x
21 CFR 820.50(b)Cited across public-safe Form 483 observations2x
21 CFR 820.80(d)Cited across public-safe Form 483 observations2x
21 CFR 820.22Cited across public-safe Form 483 observations1x
21 CFR 820.70(g)(1)Cited across public-safe Form 483 observations1x
21 CFR 820.75(b)Cited across public-safe Form 483 observations1x
21 CFR 820.90(b)(1)Cited across public-safe Form 483 observations1x

Full site report

Get the verbatim findings behind Becker Orthopedic Appliance Co.'s 3 Form 483s

Source PDFs, verbatim observations, and recurring CFR citations, so your team knows what this site gets cited for.

  • The site's full inspection history, with every Form 483 and its outcome
  • Warning letters and recalls tied to the company behind it
  • Whether recurring CFR citations get closed out or repeat