FDA-Inspected Site

Apnea Sciences Corporation

7 FDA inspections are on record for Apnea Sciences Corporation in Aliso Viejo, United States.

483· Form 483 issued

Aliso Viejo, United States · Last updated July 10, 2026

Overview

  • 7 FDA inspections are on record.
  • 7 inspections produced a Form 483.
  • The most recent recorded inspection date is 2024-09-18.

At a glance

Inspections

7

Form 483s

7

EIRs

0

Last outcome

Form 483

Inspection history

FDA inspections on record, most recent first.

InspectionCategoryOutcomeForm 483
16 Sep 2024 – 18 Sep 2024Medical Devices & Rad Health483View 483 →
16 Aug 2021 – 19 Aug 2021Medical Devices & Rad Health483View 483 →
10 Jul 2018 – 16 Jul 2018Medical Devices & Rad Health483View 483 →
28 Oct 2015 – 12 Nov 2015Medical Devices & Rad Health483On file
8 Sep 2015 – 18 Sep 2015Medical Devices & Rad Health483On file
7 Jan 2014 – 28 Jan 2014Medical Devices & Rad Health483View 483 →
6 Dec 2012Not recorded483View 483 →

Observations on record

Form 483 observations cited at this site, most recent first.

18 Sep 2024
21 CFR 820.198(a)

Lack of or inadequate complaint procedures

Cited by Kevin N Tran

18 Sep 2024
21 CFR 820.198(a)

Lack of or inadequate complaint procedures

Cited by Kevin N Tran

18 Sep 2024
21 CFR 820.30(i)

Design changes - Lack of or Inadequate Procedures

Cited by Kevin N Tran

18 Sep 2024
21 CFR 820.30(i)

Design changes - Lack of or Inadequate Procedures

Cited by Kevin N Tran

19 Aug 2021
21 CFR 820.100(a)

Lack of or inadequate procedures

Cited by Kevin N Tran, Alexandria L Capuano

Investigators

FDA investigators tied to this site in the record.

Recurring citations

CFR citation patterns observed across this site's inspections.

CitationWhat it coversCited
21 CFR 820.100(a)Cited across public-safe Form 483 observations6x
21 CFR 820.198(a)Cited across public-safe Form 483 observations5x
21 CFR 820.30(i)Cited across public-safe Form 483 observations4x
21 CFR 803.17Cited across public-safe Form 483 observations2x
21 CFR 820.184Cited across public-safe Form 483 observations2x
21 CFR 820.198(c)Cited across public-safe Form 483 observations2x
21 CFR 820.198(d)Cited across public-safe Form 483 observations2x
21 CFR 820.20(c)Cited across public-safe Form 483 observations2x
21 CFR 820.22Cited across public-safe Form 483 observations2x
21 CFR 820.30(j)Cited across public-safe Form 483 observations2x
21 CFR 820.40Cited across public-safe Form 483 observations2x
21 CFR 820.80(e)Cited across public-safe Form 483 observations2x
21 CFR 803.50(a)(2)Cited across public-safe Form 483 observations1x
21 CFR 803.52(c)(3)Cited across public-safe Form 483 observations1x
21 CFR 803.52(e)(1)Cited across public-safe Form 483 observations1x
21 CFR 820.181Cited across public-safe Form 483 observations1x
21 CFR 820.198(e)Cited across public-safe Form 483 observations1x
21 CFR 820.40(a)Cited across public-safe Form 483 observations1x
21 CFR 820.50Cited across public-safe Form 483 observations1x
21 CFR 820.50(a)Cited across public-safe Form 483 observations1x
21 CFR 820.80(d)Cited across public-safe Form 483 observations1x

Full site report

Get the verbatim findings behind Apnea Sciences Corporation's 7 Form 483s

Source PDFs, verbatim observations, and recurring CFR citations, so your team knows what this site gets cited for.

  • The site's full inspection history, with every Form 483 and its outcome
  • Warning letters and recalls tied to the company behind it
  • Whether recurring CFR citations get closed out or repeat