Overview
- 7 public-safe observations are available for this inspection.
- 7 structured CFR citations are represented.
- 3 investigators are tied to this Form 483.
Inspectional observations
Each observation cites the regulation FDA found the firm out of compliance with.
20 Aug 2013
21 CFR 211.22(d)
Procedures not in writing, fully followed
Cited by Eileen A Liu, Katherine Szestypalow, Charisse K Green
20 Aug 2013
21 CFR 211.46(b)
Equipment for Environmental Control
Cited by Eileen A Liu, Katherine Szestypalow, Charisse K Green
20 Aug 2013
21 CFR 211.100(b)
SOPs not followed / documented
Cited by Eileen A Liu, Katherine Szestypalow, Charisse K Green
20 Aug 2013
21 CFR 211.113(b)
Procedures for sterile drug products
Cited by Eileen A Liu, Katherine Szestypalow, Charisse K Green
20 Aug 2013
21 CFR 211.170(b)
Annual visual exams of drug products
Cited by Eileen A Liu, Katherine Szestypalow, Charisse K Green
Inspected site
AIApotex Inc.North York, Canada
Inspection team
Cited regulations
CFR citations associated with this Form 483.
| Citation | What it covers | Cited |
|---|---|---|
| 21 CFR 211.100(b) | Cited across public-safe Form 483 observations | 1x |
| 21 CFR 211.113(b) | Cited across public-safe Form 483 observations | 1x |
| 21 CFR 211.170(b) | Cited across public-safe Form 483 observations | 1x |
| 21 CFR 211.192 | Cited across public-safe Form 483 observations | 1x |
| 21 CFR 211.198(a) | Cited across public-safe Form 483 observations | 1x |
| 21 CFR 211.22(d) | Cited across public-safe Form 483 observations | 1x |
| 21 CFR 211.46(b) | Cited across public-safe Form 483 observations | 1x |